NeuroLiaison:NCSE発作自動遮断、バースト抑制比リアルタイム追跡、頭蓋内コンプライアンス評価
NeuroLiaisonは、高密度神経電図(ENG)から運動意図を解読して義肢を制御し、微小秒単位の生体模倣パルスで感覚求心路を刺激して自然な触覚と固有受容感覚を再建する双方向末梢神経インターフェース(PNI)を設計します。
NeuroLiaison Closed-Loop Bidirectional Neural Interface Architecture
ENG motor intent decoding, biomimetic sensory stimulation, and charge-balanced ASIC
Central System: Neural Interface Controller - Bidirectional ENG/Sensory ASIC
Clinical IoMT Nodes
- Transversal Intrafascicular Electrode (TIME)
- Low-Noise Neural Recording Front-End
- Real-Time Motor Intent Decoder
- Biomimetic Sensory Stimulation Engine
- Bionic Limb / Robotic Actuator
Architectural Layers & Regulatory Standards
- Intraneural Micro-Electrode Interface (TIME Array / Longitudinal Intrafascicular Electrodes (LIFE)): Interfacing directly with nerve axons inside individual peripheral fascicles (median, ulnar, and radial nerves).
- Neural Signal Conditioning & Artifact Blanking (Dynamic Artifact Suppression / High-CMRR Bio-Amps): Recording microvolt-level neural action potentials while suppressing stimulation artifacts and muscle EMG cross-talk.
- Intent Decoding & Neural Prosthetic Telemetry (Kalman Filter / Recurrent Neural Networks): Translating decoded firing rates into smooth, proportional prosthetic joint movements in real time.
- Biomimetic Afferent Sensory Stimulation (Charge-Balanced Biphasic Current Stimulation): Encoding fingertip pressure sensor data into patterned electrical stimulation delivered to sensory nerve fibers.
Key Metrics: < 40 ms (Closed-Loop Sensorimotor Latency) | < 1 µV RMS (ENG Recording Amplifier Noise) | 100% (Charge-Balanced Current Injection) | 10 Years (Implantable Silicone Encapsulation Lifespan)
神経連携システム、双方向末梢神経インターフェースと感覚フィードバック神経補綴
Authoritative technical engineering reference for neural liaison systems, bidirectional peripheral nerve interfaces & sensory feedback neuroprosthetics in FDA Premarket submissions, EU MDR, IEC 62304 Class C software lifecycle, ISO 13485 quality systems, and IoMT zero-trust interoperability.
Core Engineering Areas
Technical Articles
Related Cluster Architecture Specifications
- HealthVigilance — Zero-Trust IoMT Architecture, SaMD Risk Engineering & Autonomous Clinical Post-Market Vigilance
- AgenticSaMD — Autonomous Agentic Software as a Medical Device, Multi-Agent Clinical Decision Support & FDA GMLP Guardrails
- AITelemonitoring — Autonomous AI Telemonitoring, Virtual Nursing Assistants & Predictive Clinical Deterioration Scoring
- BCI2IoMT — Brain-Computer Interface IoMT Gateways, Neural Decoding & Electrophysiological Streaming